Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs forPLC UIU, AMI, Diaphragm Gas Meter, All of the time, we have been paying attention on all information to insure each product or service glad by our customers.
OEM Famous Self-supporting cable Quotes –Suspension type Polymeric Insulator – HolleyDetail:

Specifications

 

Products Type

 

SUSPENSION TYPE POLYMERIC INSULATOR 13.8 kV

SUSPENSION TYPE POLYMERIC INSULATOR 22.9 kV

 

მახასიათებლები

ერთეული

ღირებულება

ღირებულება

1

Operating voltage (Phase – Phase)

 

≤ 13,8 კვ

≥13.8 kV , ≤22.9 kV

2

Designation, model

FXB-24kV/70kN

FXB-36kV/70kN

3

სტანდარტები

IEC 61109:2008, ANSI C29.13

IEC 61109:2008, ANSI C29.13

4

Manufacturing Features
Core material

Fiberglass with Fiberglas Round Rod Bar ECR

Fiberglass with Fiberglas Round Rod Bar ECR

Insulated housing and sheds:

High consistency silicone rubber type HTV or LSR

High consistency silicone rubber type HTV or LSR

- Resistance to tracking and erosion of insulating material: Silicone rubber

Class 2A, 6kV (according to ASTM D2303 – IEC 60587)

Class 2A, 6kV (according to ASTM D2303 – IEC 60587)

Material of the coupling hardware

Forged steel

Forged steel

Galvanization of hardware

According to ASTM A153/A153M, average thickness of 86µm

According to ASTM A153/A153M, average thickness of 86µm

Types of coupling

Clevis – Tongue,

Clevis – Tongue

გასაღები

Stainless steel

Stainless steel

5

Electrical Values:
Operation voltage phase-phase

kV

10 kV, 13.2 kV to 13.8 kV

13.8 kV to 22.9 kV

Maximum voltage for the insulator Um

kV(r.m.s)

24

36

Nominal frequency

Hz

60

60

Maximum diameter of the insulating part

mm

98

98

Minimum creepage distance

mm

645

945

Minimum arcing distance

mm

210

285

Number of sheds

არა.

6

9

Sheds diameter

mm

98

98

Passage of the sheds

mm

35

35

Sheds tilt angle

°

3

3

Withstand voltage at power frequency:
- სველი

kV

≥100

≥110

- მშრალი

kV

≥130

≥140

Impulse withstand voltage 1.2/50us:

kV

- პოზიტიური

kV

≥190

≥240

Low Frequency Test Voltage (RMS to Earth)

kV

20

30

RIV Maximum at 1000 KHz

μV

10

10

6

Mechanical values:
Specified Maximum Mechanical Load (SML)

kN

70

70

Specified Mechanical Test Load (RTL)

kN

35

35

ბრუნვის მომენტი

N-მ

47

47

Core diameter

mm

16

16

წონა

kg

1.4

1.9

7

Design Tests

According to clause 10 IEC 61109

According to clause 10 IEC 61109

8

ტიპის ტესტები

According to clause 11 IEC 61109

According to clause 11 IEC 61109

9

Sampling tests

According to clause 12 IEC 61109

According to clause 12 IEC 61109

10

Individual tests

According to clause 13 IEC 61109

According to clause 13 IEC 61109

11

UV resistance tests

According to ASTM G154 and ASTM G155 or ISO 4892-3 and ISO 16474-3

According to ASTM G154 and ASTM G155 or ISO 4892-3 and ISO 16474-3


Product detail pictures:

OEM Famous Self-supporting cable Quotes –Suspension type Polymeric Insulator – Holley detail pictures


Related Product Guide:

We have quite a few great team customers very good at internet marketing, QC, and dealing with kinds of troublesome trouble while in the output approach forOEM Famous Self-supporting cable Quotes –Suspension type Polymeric Insulator – Holley, The product will supply to all over the world, such as: Jersey, Romania, Argentina, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!

Leave Your Message
vr